HK OLM 1.4 140 C

Diaphragm accumulator 1.4L 140bar
Type
Gas volume l
1.4 l
p max.
140 bar
Téléchargement du PDF
Détails produit concernant

HK OLM 1.4 140 C

Type
1
Gas volume l
1.4 l
p max.
140 bar
pma : p0
8:1
p max - p min
120 bar
A
202 mm
B
33 mm
F
G 1/2″ -14
SW
41 mm
Ø D
147 mm
Toutes les caractéristiques

Caractéristiques

Material
  • type 1: membrane NBR 
  • type 2: membrane ECO 
Application
  • Energy storage 
  • Emergency actuation 
  • Leak oil and volume compensation 
  • Shock absorption and pulsation damping 
  • Suspension of vehicles 
Connections
  • Oil side type C - female thread and male thread 
Construction type
  • installation preferably vertical, gas side top 
Temp. range
  • Type 1: -10 °C to +80 °C 
  • Type 2: -40 °C to +80 °C 
Customs tariff number
  • 84798997 
Toutes les caractéristiques

Product description

Remarques
CE-mark for diaphragm accumulators > 1.0 l gas volume
Working pressure 100 to 350 bar; min. working pressure must be 10% above gas charge pressure
max. gas filling pressure 130 bar
Description
As liquids are practically incompressible, the compressibility of a gas (in this case nitrogen) is used in hydraulic accumulators to store energy.
A hydraulic accumulator consists of two chambers (liquid side and gas side), which are separated by a flexible, gas-tight element. The liquid side is connected to the hydraulic circuit of the system. When the pressure in the system rises, the accumulator is filled with oil and the gas is compressed. If the pressure drops, the stored pressurised liquid is forced back into the circuit by expansion of the compressed gas.
Remarque relative à la commande
Pressure accumulators are available uncharged ex-warehouse. Additional costs apply upon customer request for N2-charging.
If required, please include counter nut HK MS M33 - 15 in your order.

Gamme de produits

5 Résultats
Afficher le plan coté
Désignation
Type
Gas volume l (l)
p max. (bar)
pma : p0
0.5 l
210 bar
8:1 
En savoir plus
0.75 l
210 bar
8:1 
En savoir plus
1 l
210 bar
8:1 
En savoir plus
1.4 l
140 bar
8:1 
En savoir plus
1.4 l
210 bar
8:1 
En savoir plus
Type 1: Standard
Type 2: low temperature version
p0 = gas charge pressure
pmax - pmin = admissible pressure fluctuation of the accumulator

Column selection

Type
Gas volume l (l)
p max. (bar)
pma : p0
p max - p min (bar)
A (mm)
B (mm)
F
SW (mm)
Ø D (mm)
Type 1: Standard
Type 2: low temperature version
p0 = gas charge pressure
pmax - pmin = admissible pressure fluctuation of the accumulator