PR 42-2 V4

Tube hydraul. 42x2 1.4571
Product details for

PR 42-2 V4

S
2 mm
Cas de charge I
118 bar
Cas de charge III
92 bar
Ø d2
38 mm
Tolérance diamètre extérieur +/-
0,2 mm
Tolérance diamètre intérieur +/-
0,2 mm
All characteristics

Characteristics

Construction
  • tube en acier de précision, sans soudure (étiré à froid), métrique 
Fabrication
  • métrique 
Matériau
  • Acier inoxydable X6CrNiMoTi17-12-2 (1.4571) 
Norme
  • DIN EN 10216-5 
Traitement de surface
  • CFD (décalaminé, métallique propre) / CFA (recuit brillant, métallique brillant) 
Longueur de tube
  • 5 à 7 mètres 
Customs tariff number
  • 73044100 
All characteristics

Product description

Notes
Les valeurs de pression indiquées se réfèrent à un tube droit.
Dans le cas des tuyaux cintrés, les épaisseurs de paroi correspondantes doivent être calculées de la même manière DIN EN 13480-4.
*Stainless steel tubes are supplied in manufactured lengths according to EN 10216-5. In terms of production, these are usually 6 meters (+/- 1m). Order quantities are rounded to the nearest possible total length, without cutting.
Further information
calcul analogique DIN 2413
cas de charge I: statique (jusqu'à 120 °C)
Cas de charge III : dynamique (jusqu'à 120 °C) Amplitude d'oscillation = P bar
valeur caractéristique de résistance : K 234 [N/mm²]
Coefficient de sécurité: S 1,5
résistance à la fatigue : σSch/D 190 [N/mm2]
Les tolérances: DIN EN 10305-1 (spécifications de diamètre/épaisseur de paroi)
limite d'élasticité selon DIN 10216-5 Rp 1,0 jusqu'à 50 °C

Product variants

64 Results
Show dimensional drawing
Identifier
Ø d1 (mm)
S (mm)
Cas de charge I (bar)
Cas de charge III (bar)
Details / Meter
4 mm
1 mm
600 bar
408 bar
Learn more
6 mm
0,5 mm
140 bar
109 bar
Learn more
6 mm
1 mm
400 bar
287 bar
Learn more
6 mm
1,5 mm
660 bar
442 bar
Learn more
6 mm
2 mm
915 bar
575 bar
Learn more
8 mm
1 mm
300 bar
222 bar
Learn more
8 mm
1,5 mm
495 bar
347 bar
Learn more
8 mm
2 mm
690 bar
458 bar
Learn more
10 mm
0,5 mm
105 bar
81 bar
Learn more
10 mm
1 mm
240 bar
181 bar
Learn more

Shows 10 of 64

Column selection

Ø d1 (mm)
S (mm)
Cas de charge I (bar)
Cas de charge III (bar)
Ø d2 (mm)
Tolérance diamètre extérieur +/- (mm)
Tolérance diamètre intérieur +/- (mm)